← 返回
一种基于自适应无功扰动与被动准则的多逆变器分布式电源并网微电网孤岛检测新方法
A Novel Hybrid Islanding Detection Method for Grid-Connected Microgrids With Multiple Inverter-Based Distributed Generators Based on Adaptive Reactive Power Disturbance and Passive Criteria
| 作者 | Xiaolong Chen · Yongli Li · Peter Crossley |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2019年9月 |
| 技术分类 | 系统并网技术 |
| 技术标签 | 微电网 并网逆变器 跟网型GFL 组串式逆变器 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 孤岛检测 微电网 基于逆变器的分布式电源 无功功率扰动 被动准则 并网 频率变化 |
语言:
中文摘要
本文提出了一种针对含多台逆变器分布式电源(IBDG)的并网微电网的混合孤岛检测方法。该方法结合了主动与被动检测的优势,利用不同位置IBDG对频率变化(FV)特征的一致性,引入线性无功功率扰动(RPD)技术,有效提升了孤岛检测的可靠性与响应速度。
English Abstract
In order to obtain the benefits of both passive and active methods, a well-designed hybrid islanding detection method for grid-connected microgrids with multiple inverter-based distributed generators (IBDGs) is presented in this paper. Considering that IBDGs located at different positions can detect the same frequency variation (FV) characteristics, linear reactive power disturbance (RPD) is utili...
S
SunView 深度解读
该研究直接关联阳光电源的核心业务——光伏逆变器与储能变流器(PCS)的并网安全控制。在多机并联的微电网场景下,孤岛检测的准确性是保障电网安全及设备运行的关键。该混合检测方法可优化阳光电源组串式逆变器及PowerTitan/PowerStack储能系统在复杂微电网环境下的并网算法,减少误动作并缩短检测时间。建议研发团队将其自适应扰动策略集成至iSolarCloud智能运维平台的控制逻辑中,以提升分布式能源系统的电网适应性,特别是在弱电网或多机并联场景下的稳定性表现。