← 返回

一种非对称短路故障下三相三腿逆变器并联虚拟阻抗限流策略以提高故障电流可控能力

A Current Limiting Strategy With Parallel Virtual Impedance for Three-Phase Three-Leg Inverter Under Asymmetrical Short-Circuit Fault to Improve the Controllable Capability of Fault Currents

语言:

中文摘要

本文针对电压控制型三相三腿逆变器在非对称短路故障下的限流问题,提出了一种基于并联虚拟阻抗的限流策略。该方法解决了传统电流控制模式在非对称故障下易触发电压限幅的问题,有效提升了逆变器在复杂电网故障下的故障电流可控性与系统稳定性。

English Abstract

Voltage-controlled three-phase three-leg inverters are widely applied in various occasions. The inverters are generally switched to the current-controlled mode to limit the fault currents when short-circuit faults happen. Under symmetrical fault, the inverter can be controlled as a symmetrical, three-phase current source. However, the voltage limiting will happen under asymmetrical fault. As a res...
S

SunView 深度解读

该研究直接针对光伏逆变器(尤其是组串式逆变器)在复杂电网故障下的鲁棒性问题。阳光电源的组串式逆变器在面对非对称故障时,若仅采用常规限流策略,易导致输出电压限幅及电流畸变。引入并联虚拟阻抗策略,能显著提升逆变器在弱电网或故障工况下的低电压穿越(LVRT)能力,增强对电网故障的适应性。建议研发团队将此算法集成至iSolarCloud智能运维平台下的控制固件中,以提升产品在复杂电网环境下的并网性能与可靠性。