← 返回
一种带关键负载的并网逆变器无功功率扰动观察法反孤岛策略
Reactive Power P&O Anti-Islanding Method for a Grid-Connected Inverter With Critical Load
| 作者 | Sungyoul Park · Minho Kwon · Sewan Choi |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2019年1月 |
| 技术分类 | 系统并网技术 |
| 技术标签 | 并网逆变器 微电网 光伏逆变器 控制与算法 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 并网逆变器 关键负载 反孤岛效应 无功功率 P&O法 无缝切换 间接电流控制 |
语言:
中文摘要
针对带关键负载的并网逆变器,本文提出了一种无功功率扰动观察(P&O)反孤岛方法。该方法旨在确保在电网模式切换及故障清除期间,逆变器能为关键负载提供稳定的电压,同时实现对非计划孤岛效应的快速检测,并支持逆变器在模式切换时的无缝转换。
English Abstract
A grid-connected inverter with critical loads should be able to supply a stable voltage to critical loads at the instant of a mode change as well as during clearing time while quickly detecting unintentional islanding. The indirect current control has been proposed to provide not only a stable voltage to critical loads during clearing time but also a seamless transfer of inverters at the instant o...
S
SunView 深度解读
该研究对于阳光电源的组串式逆变器及微电网解决方案具有重要意义。在工商业光伏及微电网应用中,确保关键负载在电网故障或孤岛切换期间的供电连续性是核心竞争力。该反孤岛策略可优化阳光电源iSolarCloud平台下的微电网控制算法,提升系统在复杂电网环境下的稳定性与安全性。建议研发团队关注该方法在PowerStack储能系统及组串式逆变器并网控制中的集成,以增强产品在弱电网及离网切换场景下的无缝供电能力。