基于SVPWM的并联电压源逆变器载波相位差引起的环流分析与抑制
Analysis and Suppression of Circulating Current Caused by Carrier Phase Difference in Parallel Voltage Source Inverters With SVPWM
| 作者 | Zhang Xueguang · Weiwei Li · Yi Xiao · Gaolin Wang · Dianguo Xu |
| 期刊 | IEEE Transactions on Power Electronics |
| 出版日期 | 2018年12月 |
| 技术分类 | 拓扑与电路 |
| 技术标签 | 光伏逆变器 并网逆变器 空间矢量调制SVPWM 三相逆变器 |
| 相关度评分 | ★★★★★ 5.0 / 5.0 |
| 关键词 | 并联逆变器 环流 SVPWM 载波相位差 高频电流 数学建模 逆变器控制 |
语言:
中文摘要
本文针对并联运行逆变器中的高频环流问题进行了深入研究。通过建立数学模型,揭示了由SVPWM载波相位差引起的环流频谱成分及其变化趋势,并提出了相应的抑制策略,填补了该领域对高频环流分析的空白。
English Abstract
Although high-frequency circulating current exists in parallel-operated inverters, it has not attracted as much attention as low-frequency circulating current, and thus has not been analyzed in detail previously. In this paper, a mathematical model and analysis are presented, which reveal the spectrum components and their changing trends of the circulating currents caused by carrier phase differen...