中文摘要

针对星型级联H桥STATCOM在进行正负序无功补偿时,因相电流/电压不平衡导致各相簇间有功功率分配不均的问题,本文提出了一种基于零序电压注入的簇电压平衡控制策略,并识别了负序电流补偿的有效运行区域,以解决复杂工况下的电压平衡难题。

English Abstract

In some application circumstances, both positive and negative sequence reactive power compensations are desired from the star-connected cascaded H-bridge static synchronous compensator (CHB STATCOM). However, the imbalanced phase currents/voltages will cause uneven active power flow among three clusters, which makes the cluster voltage balance more challenging. In this scenario, only zero sequence...
S

SunView 深度解读

该技术对于阳光电源的大型储能系统(如PowerTitan系列)及高压并网变流器具有重要参考价值。随着电网环境日益复杂,储能PCS在弱电网或不平衡电网下的稳定运行及无功支撑能力成为核心竞争力。级联H桥拓扑在大型储能及高压静止无功发生器中应用广泛,本文提出的零序电压注入策略能有效解决多模块间的电压均衡问题,提升系统在负序电流补偿工况下的可靠性。建议研发团队将其应用于大功率储能PCS的控制算法优化中,以增强产品在复杂电网环境下的电能质量治理能力。